Manual Euro-MERiDIAN
Chapter 5 Page 5 -5
E: SILENT SETTING
This is NOT available as a user
choice when setting the system. It
can be arranged by careful use of
the area exit tone volume levels.
Settings 0 and 1 are both silent -
setting 1 has audible 'chime' at end
of exit time.
A Site Option is available for exit and
entry tones to be generated by Keypad
sounders only
F: EXIT MODES
‘
Timed
’
mode sets the system
when the programmed exit time
has expired, provided all zones on
the exit route are clear. Any
‘
PTS
’
button fitted will be live also in
this mode.
‘
Final Door
’
mode: the setting
procedure will be completed when
a zone programmed as
‘
Final Exit
(FX)
’
is closed. This mode may also
be used for
‘
lock set
’
operation:
securing the lock completes
setting procedure, unlocking starts
entry time.
If the
‘
FX
’
zone is closed before the
remainder of the exit route is
clear, it will be
‘
stored
’
and acted
on to complete the setting
procedure only after the
remainder of the exit route is
clear.
‘
Timed/Door
’
mode: the setting
will be completed when the exit
time expires, OR when a
‘
Final Exit
’
zone is opened and closed
-
whichever occurs first (
NOT
DD243:2002 systems
).
‘PTS’
mode will override the
programmed exit time for the
area in question, and will be
endless.
Note: The PTS signal is NOT
stored. If pressed before the exit
route is clear, it will be ignored.
‘
Quickset
’
(5 seconds) is not
programmable, but is applied
automatically when an area is set
from a Keypad located outside
that area, and if intelligent
setting.
‘
Fail to Set
’
procedure will apply
if the setting procedure is not
completed within a pre
-
set time
– see
‘
SITE OPTIONS.
’
‘
Intelligent Set
’
permits the
system to automatically omit
Area B when setting with a
multiple area code including area
‘
B.
’
(See page 5
-
3)
Multiple Areas
If a Set Point programmed as
‘
IN
’
multiple areas is used, the
highest priority exit mode
programmed for those areas
‘Timed’ as lowest and ‘PTS’ as
highest will apply. Any other
areas being set will automatically
‘
Quickset.
’
On entry, the system will allow
the highest entry time applicable
to areas to which the entry door
is programmed.
NOTE: Care is required in setting
up exit modes / volumes for
‘common lobby’ areas.
Hello, im noob :)