Manual Euro-MERiDIAN
Chapter 5 Page 5 -5
E: SILENT SETTING
This is NOT available as a user
choice when setting the system. It
can be arranged by careful use of
the area exit tone volume levels.
Settings 0 and 1 are both silent -
setting 1 has audible 'chime' at end
of exit time.
A Site Option is available for exit and
entry tones to be generated by Keypad
sounders only
F: EXIT MODES
Timed
mode sets the system
when the programmed exit time
has expired, provided all zones on
the exit route are clear. Any
PTS
button fitted will be live also in
this mode.
Final Door
mode: the setting
procedure will be completed when
a zone programmed as
Final Exit
(FX)
is closed. This mode may also
be used for
lock set
operation:
securing the lock completes
setting procedure, unlocking starts
entry time.
If the
FX
zone is closed before the
remainder of the exit route is
clear, it will be
stored
and acted
on to complete the setting
procedure only after the
remainder of the exit route is
clear.
Timed/Door
mode: the setting
will be completed when the exit
time expires, OR when a
Final Exit
zone is opened and closed
-
whichever occurs first (
NOT
DD243:2002 systems
).
‘PTS’
mode will override the
programmed exit time for the
area in question, and will be
endless.
Note: The PTS signal is NOT
stored. If pressed before the exit
route is clear, it will be ignored.
Quickset
(5 seconds) is not
programmable, but is applied
automatically when an area is set
from a Keypad located outside
that area, and if intelligent
setting.
Fail to Set
procedure will apply
if the setting procedure is not
completed within a pre
-
set time
– see
SITE OPTIONS.
Intelligent Set
permits the
system to automatically omit
Area B when setting with a
multiple area code including area
B.
(See page 5
-
3)
Multiple Areas
If a Set Point programmed as
IN
multiple areas is used, the
highest priority exit mode
programmed for those areas
‘Timed’ as lowest and ‘PTS’ as
highest will apply. Any other
areas being set will automatically
Quickset.
On entry, the system will allow
the highest entry time applicable
to areas to which the entry door
is programmed.
NOTE: Care is required in setting
up exit modes / volumes for
‘common lobby’ areas.