ENGINEERING
MANUAL
Information is included relevant to the
following Euro-MERiDIAN systems, fitted
with End Station software issues 3.0 or later,
or equivalent MSX cards:
Euro-10
Euro-12
Euro-22
Euro-28
Euro-44+
Euro-134 *
Euro-256 *
* - Euro-44+ fitted with MSX Card.
This manual does NOT include information
for earlier issues
where this differs.
Bona fide alarm engineers may obtain
technical support for this product from
Castle Care-Tech Ltd. on 01344 886767
Vue de la page 0
1 2 3 4 5 6 ... 197 198

Résumé du contenu

Page 1 - ENGINEERING

ENGINEERINGMANUALInformation is included relevant to thefollowing Euro-MERiDIAN systems, fittedwith End Station software issues 3.0 or later, or equiv

Page 2

Manual Euro-MERiDIANChapter 1 Page 1 - 3"Sequentially Confirmed" alarm systems:Please note the following sequence of events for 'unconf

Page 3 - Page (ii) September 2002

Manual Euro-MERiDIANChapter 13 Page 13 - 13(vi) ASSIGNING KEYPADS and TAG READERSNOTE: All keypads and TagReaders MUST be correctlyaddressed before at

Page 4 - Issue 3·1 Page (iii)

Castle Care-Tech Ltd. EngineeringPage 13 - 14 Chapter 13Whilst programming this step, the keypad Area (A,B) keys will illuminate when that area is sel

Page 5 - Page (iv) September 2002

Manual Euro-MERiDIANChapter 13 Page 13 - 15UseD to select ‘Reader [1]’Press YES Reader is [0] Set PointPress YES to select ‘Set Point [0]’Then proce

Page 6 - Issue 3·1 Page (v)

Castle Care-Tech Ltd. EngineeringPage 13 - 16 Chapter 13Enter text, as described on page 13-3.Press YES Display When Set No [0]Selects wheth

Page 7 - Page (vi) September 2002

Manual Euro-MERiDIANChapter 13 Page 13 - 17(viii) CHANGING TIMERSThe various timers on the system are:Timer Function Range DefaultEntryTimeEntry time

Page 8 - INTRODUCTION

Castle Care-Tech Ltd. EngineeringPage 13 - 18 Chapter 13Timer Function Range DefaultSpeakerTimeTime Speaker and Keypad Bleeper outputs remains live af

Page 9 - WARRANTY

Manual Euro-MERiDIANChapter 13 Page 13 - 19(ix) SET DATE and TIMEALL log entries and the systemdisplay include time and date.This may be programmed in

Page 10

Castle Care-Tech Ltd. EngineeringPage 13 - 20 Chapter 13‘QUICKSET’ (5 seconds) is notprogrammable, but is appliedautomatically when an area isset from

Page 11 - Page 1 - 4 Chapter 1

Manual Euro-MERiDIANChapter 13 Page 13 - 21(xi) PROGRAMMING CODES and TAGSCodes may be 4-,5- or 6-digit,or proximity Tags. Using a 5- or 6-digit code

Page 12 - SYSTEM COMPONENTS

Castle Care-Tech Ltd. EngineeringPage 13 - 22 Chapter 13PROGRAMMINGPROCEDURE:With the display showing CHANGE CODES?Press YES Change Duress Codes?Pres

Page 13

Castle Care-Tech Ltd. EngineeringPage 1 - 4 Chapter 1THIS PAGE LEFT BLANK FOR NOTES

Page 14 - SYSTEM ARCHITECTURE

Manual Euro-MERiDIANChapter 13 Page 13 - 23Press NO Change Master Manager Code?Press YES Master Manager Code [******]Use number keys to insert new

Page 15 - B: Euro-12

Castle Care-Tech Ltd. EngineeringPage 13 - 24 Chapter 13 B Entry [4]Use number keys to selectlevel required.Press YES A Exit [3]Us

Page 16 - C: Euro-22

Manual Euro-MERiDIANChapter 13 Page 13 - 25(xiii) ALARM RESPONSESSilent 1st AlarmThis prevents all system sounders from becoming live until an alarm h

Page 17 - D: Euro-28

Castle Care-Tech Ltd. EngineeringPage 13 - 26 Chapter 13Repeat for other areas. Press YES Fire Starts at Digi [3]Repeat for FIRE alarms.Press

Page 18 - E: Euro-44+ EoL Mode

Manual Euro-MERiDIANChapter 13 Page 13 - 27(xiv) PROGRAMMINGOUTPUTSAny output type may beprogrammed to any of thesystem outputs. Outputs MUSTbe used w

Page 19 - F: Euro-44+ iD Mode

Castle Care-Tech Ltd. EngineeringPage 13 - 28 Chapter 13Type Default Active Restore0013SecureIntruder ANYAt alarm, after exit time started, until uns

Page 20

Manual Euro-MERiDIANChapter 13 Page 13 - 29Type Default Active Restore0036**Shunt Fault For use with shunt zones – see Technical Note “Use of Wards a

Page 21 - INTELLIGENT POWER SUPPLIES

Castle Care-Tech Ltd. EngineeringPage 13 - 30 Chapter 13Type Default Active Restore0213 Sec. Intr. A As 013 for Area/Level A events only0214 Siren A

Page 22 - SPECIFICATIONS

Manual Euro-MERiDIANChapter 13 Page 13 - 31PROGRAMMINGPROCEDURE:Note: There may be a delay of up to 10 seconds in the display updating whenjumping unu

Page 23 - D: HOUSING DIMENSIONS

Castle Care-Tech Ltd. EngineeringPage 13 - 32 Chapter 13Use number keys to select output type from table above, orD or B to scroll through available o

Page 24 - E: ELECTRICAL SPECIFICATIONS

Manual Euro-MERiDIANChapter 2 Page 2 - 1CChhaapptteerr22SYSTEM COMPONENTSThis chapter summarises the components available to complete theEuro-MERiDIAN

Page 25 - D: iD Wiring

Manual Euro-MERiDIANChapter 13 Page 13 - 331. To identify the communicator output channels to correspond to the STU output numbers, refer to table on

Page 26 - G: LOCATION OF ZONES

Castle Care-Tech Ltd. EngineeringPage 13 - 34 Chapter 13will continue to set according tocode/tag validity, using normal exit mode.It is NOT possible

Page 27 - Page 4 - 6 Chapter 4

Manual Euro-MERiDIANChapter 13 Page 13 - 35Option FunctionSet with TechnicalFaultPermits the system to be set if a Mains, Battery, Telecom Line, or ot

Page 28 - THE USER INTERFACE

Castle Care-Tech Ltd. EngineeringPage 13 - 36 Chapter 13Option Function2 Key PASelects whether the ‘2-keyPA’ function at the Keypadsis live, and if so

Page 29 - Page 5 - 2 Chapter 5

Manual Euro-MERiDIANChapter 13 Page 13 - 37(xvii) ENGINEER RESET OPTIONSOptions are available as follows:Option FunctionEngineerReset of PAFollowing a

Page 30 - (iii) ALL SYSTEMS

Castle Care-Tech Ltd. EngineeringPage 13 - 38 Chapter 13THIS PAGE LEFT BLANK FOR NOTES

Page 31 - Page 5 - 4 Chapter 5

Manual Euro-MERiDIANChapter 14 Page 14 - 1CChhaapptteerr1144TEST & DIAGNOSTIC FEATURES This chapter outlines how to access the test and diagnostic

Page 32 - F: EXIT MODES

Castle Care-Tech Ltd. EngineeringPage 14 - 2 Chapter 14ENGINEER SYSTEM SETThis permits the engineer toset / unset the system using his code.With displ

Page 33 - H: UNSET ONLY INPUT

Manual Euro-MERiDIANChapter 14 Page 14 - 3 Euro-MERiDIAN Time 13:48Note: The system will give correct communicator response to the setting, a

Page 34 - K: SYSTEM CODES / TAGS

Castle Care-Tech Ltd. EngineeringPage 14 - 4 Chapter 14Soak Control?Press YESSoak Zones [---]Insert number of zone required to be on soak, eg 023, f

Page 35 - INDICATIONS

Castle Care-Tech Ltd. EngineeringPage 2 - 2 Chapter 2Spare PCBs** Euro-10 ES PCB EUR-Euro-12 ES PCB EUR-079Euro-22 ES PCB EUR-090Euro-28 ES PCB EUR-09

Page 36 - INDICATIONS and TONES

Manual Euro-MERiDIANChapter 14 Page 14 - 5TestingSiren AnyALL outputs programmed to thattypewill become live, INCLUDING those on slot-in Digi and plug

Page 37 - Page 6 - 2 Chapter 6

Castle Care-Tech Ltd. EngineeringPage 14 - 6 Chapter 14PressA to make all siren and strobe outputs live, so that display shows alarm current. Press0 t

Page 38 - (ii) Display characteristics

Manual Euro-MERiDIANChapter 14 Page 14 - 7Slow scanIs in progress . .System ceases normal zone scanning to permit the normal (mid) voltage on the iD l

Page 39 - Page 6 - 4 Chapter 6

Castle Care-Tech Ltd. EngineeringPage 14 - 8 Chapter 14THIS PAGE LEFT BLANK FOR NOTES

Page 40 - PARTITIONING THE SYSTEM

Manual Euro-MERiDIANChapter 15 Page 15 - 1CChhaapptteerr1155SYSTEM LOGS This chapter summarises the system log facilities of Euro-MERiDIAN.Logs are fu

Page 41 - D: Area Sounders

Castle Care-Tech Ltd. EngineeringPage 15 - 2 Chapter 15Fault CodesFault codes shown in thesystem logs include a numericcode to identify the individual

Page 42 - EMERGENCY ALARMS

Manual Euro-MERiDIANChapter 15 Page 15 - 3 15/09 08:14:15 AB EXITPressC Mary Smith Manager 002 Etc.Press NO Access Log?Provides option to view Acces

Page 43 - E: CALL SYSTEMS

Castle Care-Tech Ltd. EngineeringPage 15 - 4 Chapter 15System activities that will beentered in the logs include:UnsetFinal SetSecure SetOnly if ‘Conf

Page 44 - REMOTE SIGNALLING

Manual Euro-MERiDIANChapter 16 Page 16 - 1CChhaapptteerr1166Ward Control and Shunt ZonesThis Chapter examines two methods of extending the operating f

Page 45 - Page 9 - 2 Chapter 9

Castle Care-Tech Ltd. EngineeringPage 16 - 2 Chapter 16operation MUST be those onwhich the zones are live (ie asshown in the table on page 4-5).Tags f

Page 46 - Digi Reply Signal

Manual Euro-MERiDIANChapter 3 Page 3 - 1CChhaapptteerr33SYSTEM ARCHITECTUREThis chapter identifies how Euro-MERiDIAN system components wiretogether, a

Page 47 - CONFIRMATION SIGNALLING

Manual Euro-MERiDIANChapter 16 Page 16 - 3Programming a Ward:With the display showing ASSIGN KEYPADS/ READERS?Press YES Address [0]Sele

Page 48 - OPERATION:

Castle Care-Tech Ltd. EngineeringPage 16 - 4 Chapter 16 Ward Control Name?Permits name to be programmed for Ward Control Point to simplify locating th

Page 49 - REQUIREMENTS

Manual Euro-MERiDIANChapter 16 Page 16 - 5Associated Outputs:It is recommended that a‘Follow Zone’ output and‘Shunt fault’ output beprogrammed for eac

Page 50 - Chapter 9 Page 9 - 7

Castle Care-Tech Ltd. EngineeringPage 16 - 6 Chapter 16Programming the Shunt Zone and List.With the display showing CHANGE ZONES?Press YES Zone Number

Page 51 - Page 9 - 8 Chapter 9

Manual Euro-MERiDIANChapter 16 Page 16 - 7Programming the OutputsWith the display showing CHANGE OUTPUTS?Press YES End Station Outputs?Press NO to mov

Page 52 - Patent applied for

Castle Care-Tech Ltd. EngineeringPage 16 - 8 Chapter 16THIS PAGE LEFT BLANK FOR NOTES

Page 53 - Page 9 - 10 Chapter 9

Manual Euro-MERiDIANChapter 17 Page 17 - 1CChhaapptteerr1177Use of Output ModulesThis Chapter outlines the use of Output Modules in the expansion of

Page 54 - INSTALLATION

Castle Care-Tech Ltd. EngineeringPage 17 - 2 Chapter 17TERMINAL CONNECTIONS If the Output Module is plugged onto anIntelligent Power Supply, all conne

Page 55 - No. 6 round-head

Manual Euro-MERiDIANChapter 17 Page 17 - 3WIRING THE UNITRS-485 Wiring:The unit must be wired tothe RS-485 keypad bus,exactly as described forkeypads

Page 56 - DANGEROUS

Castle Care-Tech Ltd. EngineeringPage 17 - 4 Chapter 17PROGRAMMING THE OUTPUTSAny output type may beprogrammed to any output. The range of output type

Page 57 - AND enabled in the

Castle Care-Tech Ltd. EngineeringPage 3 - 2 Chapter 3B: Euro-12Max 12 End of Line Zones.Normally supplied with STANDARD Keypads

Page 58 - (i) THE Euro-10 END STATION

Manual Euro-MERiDIANChapter 18 Page 18 - 1CChhaapptteerr1188ACCESS CONTROL with Euro-MERiDIANThis chapter outlines how to install and programme the Ac

Page 59 - (ii) The Euro-12 END STATION

Castle Care-Tech Ltd. EngineeringPage 18 - 2 Chapter 18B: SYSTEM ARCHITECTUREC: INSTALLATIONThe general installation notes(see Chapter 10) are applica

Page 60 - Slotfor DigiModem

Manual Euro-MERiDIANChapter 18 Page 18 - 3D: The Door Station NOTE issue 2 PCB shownIssue 1 Door Station pcbs doNOT have the full range ofoptions, nor

Page 61 - Socket for

Castle Care-Tech Ltd. EngineeringPage 18 - 4 Chapter 18E: WIRING RS.485 CommunicationsTerminals D1,3,4 should bewired to the Euro-MERiDIANsystem as sh

Page 62 - (vi) SET/UNSET TAG READERS

Manual Euro-MERiDIANChapter 18 Page 18 - 5Relay capable of switching upto 50 volts, up to 10 amps. This may be used to switch theinternal supply, or a

Page 63

Castle Care-Tech Ltd. EngineeringPage 18 - 6 Chapter 18F: Addressing the UnitsThe door is addressed bymeans of the coding switcheson the Door Station,

Page 64 - (viii) OUTPUT MODULE

Manual Euro-MERiDIANChapter 18 Page 18 - 7Use number keys to programme time door is permitted to be open before triggering an alarm (max 250 secs).Pre

Page 65 - (ix) INTELLIGENT POWER

Castle Care-Tech Ltd. EngineeringPage 18 - 8 Chapter 18NOTES: If zone is programmed as ‘isolated’ then monitoring will be SOLELY at the Door Station.I

Page 66 - INTERFACE

Manual Euro-MERiDIANChapter 19 Page 19 - 1CChhaapptteerr1199GUARD TOUR SYSTEMS WITH Euro-MERiDIANThis chapter outlines a further application for the

Page 67 - Page 10 - 14 Chapter 10

Castle Care-Tech Ltd. EngineeringPage 19 - 2 Chapter 19C: Installing and Wiring the unitsThe installation and Wiring ofINTERNAL units is identical tot

Page 68 - WIRING THE SYSTEM

Manual Euro-MERiDIANChapter 3 Page 3 - 3C: Euro-22Max 22 End of Line zonesNormally supplied with DELUXEKeypadsNOTE: Keypad zones are NOTavailable if &

Page 69 - C: WIRING SPECIFICATIONS

Manual Euro-MERIDIANChapter 20 Page 20 - 1CChhaapptteerr2200Installing the Euro-COM 9600DigiModemThis chapter provides the information needed to inst

Page 70 - E. END of LINE DETECTION

Castle Care-Tech Ltd. EngineeringPage 20 – 2 Chapter 20

Page 71 - SINGLE RESISTOR WIRING

Manual Euro-MERIDIANChapter 20 Page 20 - 3A: Features% Ademco and Scantronic fast-format compatible% Extended Format reporting - SIA Format % 4 Alarm

Page 72 - DOUBLE RESISTOR WIRING

Castle Care-Tech Ltd. EngineeringPage 20 – 4 Chapter 20End Station, ALL POWER MUSTBE DISCONNECTED.The card must be slotted intothe correct socket (la

Page 73 - System response cannot

Manual Euro-MERIDIANChapter 20 Page 20 - 5by the grommet supplied, andsecured in place with the cable-tie, thus:NOTE: The PCB layout variesbetween th

Page 74 - Chapter 11 Page 11 - 7

Castle Care-Tech Ltd. EngineeringPage 20 – 6 Chapter 20THIS PAGE HAS BEEN LEFT BLANK FOR NOTES

Page 75 - NOTE: When a Zone Expander

Manual Euro-MERiDIANChapter 21 Page 21 - 1CChhaapptteerr2211ARC Signalling with the Digi-ModemThis chapter explains how to set up Euro-MERiDIAN system

Page 76 - READINGS

Castle Care-Tech Ltd. EngineeringPage 21 - 2 Chapter 21ARC SIGNALLINGRed Care SignallingNote this requires a separateSTU, which may be wired fromor pl

Page 77 - Important Notes for

Manual Euro-MERiDIANChapter 21 Page 21 - 3 Choose Format[0] Fast 4.8.1Press Use number keys, or D to select signalling format.0 = fast format 4.8.11 =

Page 78 - (i) SAB Connections

Castle Care-Tech Ltd. EngineeringPage 21 - 4 Chapter 21If selected as ‘retry same’ and number of redials reached, tries next number, etc.When using SM

Page 79 - (iv) Output Module Outputs

Castle Care-Tech Ltd. EngineeringPage 3 - 4 Chapter 3D: Euro-28Maximum 28 zones: 20 iD points plus 8 EoL zones.Normally supplied with DELUXEKeypads.N

Page 80 - Chapter 11 Page 11 - 13

Manual Euro-MERiDIANChapter 21 Page 21 - 5 Digi 01 is [001] FirePress YESRepeat for Digi channels 2 to 8 (or 16 if permitted by format)Press NO to abo

Page 81 - Output Identification

Castle Care-Tech Ltd. EngineeringPage 21 - 6 Chapter 21CONTENT TYPES AVAILABLE.The signalling requirementsfor "extended format"reporting may

Page 82 - Dual-path signalling

MANUAL Euro-MERiDIANChapter 22 Page 22 - 1CChhaapptteerr2222DOWNLOADING WITH Euro-MERiDIANThis chapter outlines the features and benefits available fr

Page 83 - (ii) A Plug-on STU / Dual

Castle Care-Tech Ltd. EngineeringPage 22 - 2 Chapter 22Control from the PCThe PC provides fullprogramming facilities for thesystem. Additionally, full

Page 84 - COMPONENTS

MANUAL Euro-MERiDIANChapter 22 Page 22 - 3Priority:ARC and SMS signalling willALWAYS take priority overcommunication with the PC. Within the block of

Page 85 - C: POWERING UP

Castle Care-Tech Ltd. EngineeringPage 22 - 4 Chapter 22Use number keys to programme host modem telephone number (up to 20 characters).Press YES Signal

Page 86 - ™ ™ ™ ™ ™ ™ ™[7]

MANUAL Euro-MERiDIANChapter 23 Page 23 - 1CChhaapptteerr2233SMS Text Messages from Euro-MERiDIANThis chapter explains the facility to transmit text me

Page 87 - Indications Test

Castle Care-Tech Ltd. EngineeringPage 23 - 2 Chapter 23Message Groups available:CONTENT TYPE:01 Set All set events (by area/level)02 Unset All unset e

Page 88 - PROGRAMMING THE BASICS

MANUAL Euro-MERiDIANChapter 23 Page 23 - 3TestingIf live testing is conducted to a suitable telephone, please bear in mind that a delay in receiptis l

Page 89 - EXIT ENGINEER MENU

Castle Care-Tech Ltd. EngineeringPage 23 - 4 Chapter 23 Choose Format[0] Fast 4.8.1Press Use number keys, or D to select signalling format:07 = SMS Te

Page 90 - PRINCIPLES

Manual Euro-MERiDIANChapter 3 Page 3 - 5E: Euro-44+ EoL Mode Maximum 44 End of Line zones.Normally supplied with DELUXEKeypads.For details with MSX Ca

Page 91 - OPTIONS:

MANUAL Euro-MERiDIANChapter 23 Page 23 - 5 Low Bat Report No [0]Leave at default (No)Press YES AC Fail Report No [0]Leave at default

Page 92 - (iii) MODE SELECTION

Castle Care-Tech Ltd. EngineeringPage 23 - 6 Chapter 23Initialisation and Test ProcedureBefore SMS messages can besent to a mobile ‘phone, it isnecess

Page 93 - (v) ZONE PROGRAMMING

Manual Euro-MERiDIANChapter 24 Page 24 - 1CChhaapptteerr2244SYSTEM EXPANSION and ENHANCEMENTThis chapter highlights the means of providing additional

Page 94

Castle Care-Tech Ltd. EngineeringPage 24 - 2 Chapter 24Cards Available:MSX-134This card expands themaximum capacity of the Euro-44+ to 134 zones, in 8

Page 95 - Zone types:

Manual Euro-MERiDIANChapter 24 Page 24 - 3MSX-256This card expands themaximum capacity of the Euro-44+ to 256 zones with 14simultaneous areas. The num

Page 96

Castle Care-Tech Ltd. EngineeringPage 24 - 4 Chapter 24ADDITIONAL FACILITIES WITH MSX CARDSRS-232 ConnectionA connector is provided on the MSX Card to

Page 97 - SECURITY PATTERNS

Manual Euro-MERiDIANChapter 25 Page 25-1CChhaapptteerr2255CCTV or LIGHTING CONTROL WITHEURO-MERiDIANThis chapter suggests further applications for the

Page 98 - ZONE ATTRIBUTES

Castle Care-Tech Ltd EngineeringPage 25-2 Chapter 25Programming the Outputs:Select Output type 035 asdescribed on page 13-2Output xx [035]Follow Zo

Page 99 - PROGRAMMING STEPS

Manual Euro-MERiDIANAppendix A Page A - 1AAppppeennddiixxAAFAULTFINDING Euro-MERiDIANThis chapter provides assistance to identifying and eliminatingpo

Page 100 - (vi) ASSIGNING KEYPADS

Castle Care-Tech Ltd. EngineeringPage A - 2 Appendix ATELECOMS / SIGNALLING RELATED MESSAGESMODEMFAULTEnd Station unable to communicate with COM9600 D

Page 101

Castle Care-Tech Ltd. EngineeringPage 3 - 6 Chapter 3F: Euro-44+ iD ModeMaximum 44 zones: 30 iD points plus 14 EoL zones.Normally supplied with DELUX

Page 102 - DISPLAYS

Manual Euro-MERiDIANAppendix A Page A - 3SYSTEM COMMUNICATIONS (RS-485) AND KEYPAD PROBLEMSDEVICEFAIL xxxDevice on RS-485communicationsbus failing to

Page 103 - Page 13 - 16 Chapter 13

Castle Care-Tech Ltd. EngineeringPage A - 4 Appendix APOWER SUPPLY, etc.BATTERYFAULT xxxBattery Fuse (F4)failed, ORBattery not present, ORBattery volt

Page 104 - (viii) CHANGING TIMERS

Manual Euro-MERiDIANAppendix A Page A - 5INDICATIONS ASSOCIATED WITH ENGINEER MENUEngineerAccessDeniedAccess to Engineer menu NOT possible, as system

Page 105 - PROGRAMMING PROCEDURE:

Castle Care-Tech Ltd. EngineeringPage A - 6 Appendix ATHIS PAGE LEFT BLANK FOR NOTESCastle Care-Tech Ltd. welcome suggestions forexpanding this append

Page 106 - (x) EXIT MODES

Manual Euro-MERiDIANAppendix B Page B - 1AAppppeennddiixxBBPRINCIPAL CHANGES to Euro-MERiDIANThis chapter summarises the principal changes that have b

Page 107

Castle Care-Tech Ltd. EngineeringPage B - 2 Appendix BFunction Summary of changeIssue 2.03 - July 2000Downloading Accepts 'Unset' whilst in

Page 108 - CODE CAPABILITIES

Manual Euro-MERiDIANAppendix A Page A - 3Function Summary of changeIssue 3·1 – September 2002MasterManager CodeNo longer Sets/Unsets the system.Page 5

Page 109 - PROCEDURE:

Castle Care-Tech Ltd. EngineeringPage B - 4 Appendix BThis Page has been left Blank for Notes

Page 110 - Chapter 13 Page 13 - 23

Castle Care-Tech Ltd.North Street, Winkfield, Windsor, Berkshire, SL4 4SYt Sales: 01344 887788 Technical Support: 01344 886767f 01344 890024 e sales@

Page 111 - Page 13 - 24 Chapter 13

Euro-MERiDIANIssue 3·1 Page (i)Euro-MERiDIANENGINEERING MANUAL - CONTENTSThis manual provides the information necessary to successfullydesign, install

Page 112 - (xiii) ALARM RESPONSES

Manual Euro-MERiDIANChapter 3 Page 3 - 7G: LOCATING COMPONENTSThese components all connectvia the RS-485 bus, and may bewired in any order.Avoid sitin

Page 113 - SETTING systems:

Castle Care-Tech Ltd. EngineeringPage 3 - 8 Chapter 3TMZ UNITSTMZ units provide twoadditional zones each, plus twooutputs – one of which isdedicated

Page 114 - (xiv) PROGRAMMING

Manual Euro-MERiDIANChapter 4 Page 4 - 1CChhaapptteerr44SPECIFICATIONSThis chapter outlines the essential specifications for the Euro-MERiDIAN range.C

Page 115

Castle Care-Tech Ltd. EngineeringPage 4 - 2 Chapter 4C: OUTPUT CAPABILITIESAt End Station:Hold Off 650mA(continuous)Max 800mA in alarmOutputs 1 – 2 80

Page 116

Manual Euro-MERiDIANChapter 4 Page 4 - 3E: ELECTRICAL SPECIFICATIONSMainsSupply230v (220 to 240v) AC.Max 250mA Fuse 1.2A PS: 1½A PS2½A PS150mA250mA500

Page 117

Castle Care-Tech Ltd. EngineeringPage 4 - 4 Chapter

Page 118

Manual Euro-MERiDIANChapter 4 Page 4 - 5G: LOCATION OF ZONESThe zones on the system are distributed as follows:Euro- 10 12 22 28 44+ 134 256ModeiD EoL

Page 119 - Page 13 - 32 Chapter 13

Castle Care-Tech Ltd. EngineeringPage 4 - 6 Chapter 4THIS PAGE LEFT BLANK FOR NOTES

Page 120 - ALL SYSTEMS

Manual Euro-MERiDIANChapter 5 Page 5 -1CChhaapptteerr55THE USER INTERFACEThis chapter outlines how the user interface of Euro-MERiDIAN hasbeen design

Page 121 - (xvi) SITE OPTIONS

Castle Care-Tech Ltd. EngineeringPage 5 - 2 Chapter 5If a multiple area code is enteredat a suitable Keypad, when someof the relevant areas are set a

Page 122

Castle Care-Tech Ltd. EngineeringPage (ii) September 2002QQuuiicckkSSeeaarrcchhEEuurroo--MMEERRiiDDIIAANN––MMeennuuSSttrruuccttuurreeThis chapter summ

Page 123 - Repeat for other options to:

Manual Euro-MERiDIANChapter 5 Page 5 -3c) INTELLIGENT SETTING(i) LEVEL SETTINGThis will function only if a codevalid for ‘A’ (ALL) is used to set the

Page 124 - DIGI-MODEM

Castle Care-Tech Ltd. EngineeringPage 5 - 4 Chapter 5‘AB’ code at‘A’ keypad will unset only A‘B’ code at ‘AB’ keypad will unset only B. etc.The syste

Page 125 - Page 13 - 38 Chapter 13

Manual Euro-MERiDIANChapter 5 Page 5 -5E: SILENT SETTINGThis is NOT available as a userchoice when setting the system. It can be arranged by careful

Page 126 - BATTERY LOAD TEST

Castle Care-Tech Ltd. EngineeringPage 5 - 6 Chapter 5G: KEYSWITCH OPERATIONThis is an alternative means ofsetting the system, using a keyoperated swi

Page 127 - ENGINEER FORCE SET

Manual Euro-MERiDIANChapter 5 Page 5 -7I: FAIL TO SETIf the exit procedure is notcorrectly completed, a ‘Fail to Set’warning may be used. The time de

Page 128 - ENGINEER TEST FACILITIES

Castle Care-Tech Ltd. EngineeringPage 5 - 8 Chapter 5Additionally, codes / tags may be restricted to specific area(s), and to set only or unset only.

Page 129 - Outputs Tests

Manual Euro-MERiDIANChapter 6 Page 6 - 1CChhaapptteerr66INDICATIONS and TONESThis chapter explains the indications available to the user, and theoptio

Page 130 - FACILITIES

Castle Care-Tech Ltd. EngineeringPage 6 - 2 Chapter 6d) BacklightingLCDs and Keypad keys arebacklit. The backlighting willilluminate at the start of e

Page 131 - Page 14 - 6 Chapter 14

Manual Euro-MERiDIANChapter 6 Page 6 - 3g) Display Options(i) Customise Text StringsThe ‘area setting’ text stringscan be programmed to makethe displa

Page 132 - Calibrating ZEM iD output

Castle Care-Tech Ltd. EngineeringPage 6 - 4 Chapter 6THIS PAGE LEFT BLANK FOR NOTES

Page 133 - Page 14 - 8 Chapter 14

Issue 3·1 Page (iii)Main Menu Sub Menu Function Refb) ENGINEER MENUCLEAN START?Revert all programming to factory defaults.Does NOT clear system logs.

Page 134 - SYSTEM LOGS

Manual Euro-MERiDIANChapter 7 Page 7 - 1CChhaapptteerr77PARTITIONING THE SYSTEMThis chapter identifies the alternative methods of sub-dividing thesyst

Page 135 - VIEWING LOGS

Castle Care-Tech Ltd. EngineeringPage 7 - 2 Chapter 7relevant to areas for which theentry route is valid will apply.c) Wards and ShuntsAdditional part

Page 136 - Chapter 15 Page 15 - 3

Manual Euro-MERiDIANChapter 8 Page 8 - 1CChhaapptteerr88EMERGENCY ALARMSThis chapter discusses the facilities included in Euro-MERiDIAN foremergency s

Page 137

Castle Care-Tech Ltd. EngineeringPage 8 - 2 Chapter 8B: FIRE ALARMSThe system can accept Firedetectors directly into zonesprogrammed accordingly or,al

Page 138 - Ward Control and Shunt Zones

Manual Euro-MERiDIANChapter 9 Page 9 - 1CChhaapptteerr99REMOTE SIGNALLINGThis chapter summarises the options available for remote signallingfrom the s

Page 139 - Operation of the Ward

Castle Care-Tech Ltd. EngineeringPage 9 - 2 Chapter 9C: AREA SIGNALLING‘Set/Unset’ ‘Intruder’ ‘Hold Up’‘PA’ and ‘Confirmation’ signalsare available fo

Page 140 - Programming a Ward:

Manual Euro-MERiDIANChapter 9 Page 9 - 3arm Isolates’ (in ‘SITE OPTIONS’)is selected, in which case thezone will remain isolated untilmanually reset (

Page 141 - 2. SHUNTS

Castle Care-Tech Ltd. EngineeringPage 9 - 4 Chapter 9E: SEQUENTIAL CONFIRMATION SIGNALLINGDD243:2002 Compliance All Euro-MERiDIAN modelsinclude necess

Page 142 - Operation of the Shunt

Manual Euro-MERiDIANChapter 9 Page 9 - 5OPERATION:a) Normal operationThe first zone to alarm willcause an ‘intruder’ signal to besent to the ARC, whic

Page 143 - Zone and List

Castle Care-Tech Ltd. EngineeringPage 9 - 6 Chapter 9COMPLIANCE WITH SPECIFIC REQUIREMENTSa) Basic OperationNormal operation of a"Sequentially Co

Page 144 - Programming the

Castle Care-Tech Ltd. EngineeringPage (iv) September 2002Main Menu Sub Menu Function RefCHANGE TIMERS?Programming of all system timers (except Soak Te

Page 145 - Page 16 - 8 Chapter 16

Manual Euro-MERiDIANChapter 9 Page 9 - 7b) Means of Completion ofSettingDD243:2002 permits a variety of methods. These should be considered carefully

Page 146 - Use of Output Modules

Castle Care-Tech Ltd. EngineeringPage 9 - 8 Chapter 9(ii) Unlocking initial entry door disables all means of confirmation:Wire lock contacts as "

Page 147 - TERMINAL CONNECTIONS

Manual Euro-MERiDIANChapter 9 Page 9 - 9e) Additional FacilitiesAdditional facilities are available for use in conjunction with Sequential Confirmatio

Page 148 - Outputs Wiring:

Castle Care-Tech Ltd. EngineeringPage 9 - 10 Chapter 9THIS PAGE LEFT BLANK FOR NOTES

Page 149 - PROGRAMMING THE

Manual Euro-MERiDIANChapter 10 Page 10 - 1CChhaapptteerr1100INSTALLATIONThis chapter describes the recommended procedure for installingEuro-MERiDIAN.A

Page 150 - A: FEATURES

Castle Care-Tech Ltd. EngineeringPage 10 - 2 Chapter 10B: MOUNTING THE EQUIPMENTMount the equipment carefullyin suitable locations, notingparticularly

Page 151 - C: INSTALLATION

Manual Euro-MERiDIANChapter 10 Page 10 - 3C: MAINS CONNECTIONMAINSELECTRICITY ISDANGEROUSMAINS connection must beperformed by a qualifiedelectrician,

Page 152 - D: The Door Station

Castle Care-Tech Ltd. EngineeringPage 10 - 4 Chapter 10G: POWER-UP INITIALISATIONPre Power-Up ChecksPrior to powering up thesystem, a final check shou

Page 153 - E: WIRING

Manual Euro-MERiDIANChapter 10 Page 10 - 5H: THE PRINTED CIRCUIT BOARD LAYOUTS(i) THE Euro-10 END STATIONAVAILABILITY TO BE ANNOUNCEDTerminal Allocati

Page 154 - Chapter 18 Page 18 - 5

Castle Care-Tech Ltd. EngineeringPage 10 - 6 Chapter 10(ii) The Euro-12 END STATIONTerminal Allocations:G AC input 1 Mains earth 2-3

Page 155 - Access Control

Issue 3·1 Page (v)Main Menu Sub Menu Function RefINTELLIGENTSET?Selection of intelligent setting and programming of associated 'intelligent'

Page 156 - (ii) Programming the

Manual Euro-MERiDIANChapter 10 Page 10 - 7 (iii) The Euro-22 and 28 END STATIONTerminal Allocations:G AC input 1 Mains earth 2-3

Page 157 - Facility and DD243

Castle Care-Tech Ltd. EngineeringPage 10 - 8 Chapter 10(iv) THE Euro-44+ END STATIONFuse Allocations:F1: +12v at terminals H 800mA (O4)F2: +12v at te

Page 158 - Euro-MERiDIAN

Manual Euro-MERiDIANChapter 10 Page 10 - 9(v) KEYPADSNOTE: Deluxe Keypad shown. Standard Keypad has no zone or outputterminals.Zones are available onl

Page 159 - E: SYSTEM LOGS

Castle Care-Tech Ltd. EngineeringPage 10 - 10 Chapter 10Terminal AllocationsD RS.485 1 0v 2 +12v 3 ‘A’ 4‘B’E iD bus 1 0v 2 +1

Page 160 - DigiModem

Manual Euro-MERiDIANChapter 10 Page 10 - 11(viii) OUTPUT MODULEWhen the Output Module isplugged onto an IntelligentPower Supply, all connectionsare au

Page 161 - Page 20 – 2 Chapter 20

Castle Care-Tech Ltd. EngineeringPage 10 - 12 Chapter 10(ix) INTELLIGENT POWER SUPPLYNOTE: The battery shouldNOT be connected until‘Battery Fault’ is

Page 162 - D: Fitting the Euro-COM

Manual Euro-MERiDIANChapter 10 Page 10 - 13(x) PLUG-ON RELAY INTERFACEThis interface may be plugged onto Euro-44+ (or 134/256) EndStations, and Output

Page 163 - E: PSTN Wiring

Castle Care-Tech Ltd. EngineeringPage 10 - 14 Chapter 10THIS PAGE LEFT BLANK FOR NOTES

Page 164 - G: Initialisation

Manual Euro-MERiDIANChapter 11 Page 11 - 1CChhaapptteerr1111WIRING THE SYSTEMThis chapter describes how the system should be wired for maximum effecti

Page 165 - Page 20 – 6 Chapter 20

Castle Care-Tech Ltd. EngineeringPage 11 - 2 Chapter 11C: WIRING SPECIFICATIONSThe following specifications must be observed when installing Euro-MERi

Page 166 - ARC Signalling with the Digi

Castle Care-Tech Ltd. EngineeringPage (vi) September 2002Main Menu Sub Menu Function RefSET UP DIGI / SMS?Programming of information relevant to remot

Page 167

Manual Euro-MERiDIANChapter 11 Page 11 - 3D: RS.485 COMMUNICATIONS See wiring specifications onpage 11-2.A maximum of 30 devices(including the End Sta

Page 168

Castle Care-Tech Ltd. EngineeringPage 11 - 4 Chapter 11WIRINGSee wiring specifications on page 11-2.Single- or Double-resistor EoL wiring may be used.

Page 169 - Page 21 - 4 Chapter 21

Manual Euro-MERiDIANChapter 11 Page 11 - 5DOUBLE RESISTOR WIRING This is suitable for all systemsinstalled to BS.4737, or toEN.50131.The 2K2 resistor

Page 170

Castle Care-Tech Ltd. EngineeringPage 11 - 6 Chapter 11F: iD WiringCastle Care-Tech Ltd. is a permitted user of iD.See wiring specifications onpage 11

Page 171 - CONTENT TYPES AVAILABLE

Manual Euro-MERiDIANChapter 11 Page 11 - 7The standard wiringconvention is YELLOW for the iD Line +, and BLUE for the iD Line –, which thus match the

Page 172 - DOWNLOADING WITH

Castle Care-Tech Ltd. EngineeringPage 11 - 8 Chapter 11HINT: It will be found beneficialfor subsequent maintenance andfaultfinding purposes, to have a

Page 173 - PLANNING THE CALLS

Manual Euro-MERiDIANChapter 11 Page 11 - 9G: iD COMMISSIONING READINGSOn completion of theinstallation, it is essential thatthe commissioning readings

Page 174 - Priority:

Castle Care-Tech Ltd. EngineeringPage 11 - 10 Chapter 11Table of resistance readings for measurement at step 6, above:No of biscuitsNominalresistanceN

Page 175

Manual Euro-MERiDIANChapter 11 Page 11 - 11H: OUTPUTS WIRINGWhen wiring outputs, do NOT exceed the maximum rating for individual outputs, or for the s

Page 176 - MERiDIAN

Castle Care-Tech Ltd. EngineeringPage 11 - 12 Chapter 11(ii) End Station Outputs(iii) Zone Expander Unit OutputsNOT AVAILABLE ON 4-ZONE ZEM USED WITH

Page 177 - Initialisation

Manual Euro-MERiDIANChapter 1 Page 1 - 1CChhaapptteerr11INTRODUCTIONThe Euro-MERiDIAN range has beendesigned to offer a choice ofoptions to suit most

Page 178

Manual Euro-MERiDIANChapter 11 Page 11 - 13(v) Keypad OutputsAVAILABLE ON DELUXE KEYPAD ONLY - NOT standard Keypad.(vi) Set/Unset Tag Reader Outputs,

Page 179 - _ _ _ _ _ _ _ _ _ _ _

Castle Care-Tech Ltd. EngineeringPage 11 - 14 Chapter 11(ix) Plug-on Relay InterfaceDEDICATED OUTPUTS Note: Polarity shown is inALARM condition. In no

Page 180 - [ ]

Manual Euro-MERiDIANChapter 11 Page 11 - 15J: COMMUNICATIONS OUTPUTS(i) A Stand-Alone STU / Dual-path signalling deviceEuro-22 and 28A 10-pin connecto

Page 181 - Communication Failure:

Castle Care-Tech Ltd. EngineeringPage 11 - 16 Chapter 11(ii) A Plug-on STU / Dual-path signalling deviceEuro-44+ and aboveAny communicating devicewith

Page 182 - ENHANCEMENT

Manual Euro-MERiDIANChapter 12 Page 12 - 1CChhaapptteerr1122POWERING UP and ADDRESSINGCOMPONENTSThis chapter explains how to address the various syste

Page 183 - Cards Available:

Castle Care-Tech Ltd. EngineeringPage 12 - 2 Chapter 12To address these items, identify the address coding switches,and open the switches to addup to

Page 184

Manual Euro-MERiDIANChapter 12 Page 12 - 3Full programming of keypadaddressing, etc. is performed as follows:From initial power up: ADDRESS

Page 185 - Page 24 - 4 Chapter 24

Castle Care-Tech Ltd. EngineeringPage 12 - 4 Chapter 12NOTES:Keypad 00 MUST be used thefirst time Engineer menu isaccessed, and until remainingKeypads

Page 186 - EURO-MERiDIAN

Manual Euro-MERiDIANChapter 13 Page 13 - 1CChhaapptteerr1133PROGRAMMING THE BASICSThis chapter explains how to programme a Euro-MERiDIAN system tomeet

Page 187 - Outputs:

Castle Care-Tech Ltd. EngineeringPage 13 - 2 Chapter 13This gives access to a number of ‘sub’ menus, each of whichenables a system function, orgroup o

Page 188 - FAULTFINDING Euro-MERiDIAN

Castle Care-Tech Ltd. EngineeringPage 1 - 2 Chapter 1COMPLIANCE STATEMENTThe Euro-MERiDIANrange complieswith requirementsof the European"EMC Dire

Page 189

Manual Euro-MERiDIANChapter 13 Page 13 - 3B: GENERAL PRINCIPLESThe various functions areselected and manipulated asfollows:Key In main menu:In sub men

Page 190 - Appendix A Page A - 3

Castle Care-Tech Ltd. EngineeringPage 13 - 4 Chapter 13C: NON VOLATILE MEMORYThe End Station is fitted with amemory chip to retain allprogrammed infor

Page 191 - Page A - 4 Appendix A

Manual Euro-MERiDIANChapter 13 Page 13 - 5 (iii) MODE SELECTIONThis programmes whether theEnd Station and any ZoneExpanders enabled will be usedin End

Page 192 - Appendix A Page A - 5

Castle Care-Tech Ltd. EngineeringPage 13 - 6 Chapter 13(iv) INSTALL ZEMsAny Zone Expander Modulesfitted to the system must beenabled. They will automa

Page 193 - Page A - 6 Appendix A

Manual Euro-MERiDIANChapter 13 Page 13 - 7System Zone map:The zones on the system are distributed as follows:Euro- 10 12 22 28 44+ 134 256ModeiD EoL E

Page 194

Castle Care-Tech Ltd. EngineeringPage 13 - 8 Chapter 13Zone types:The zone types available are:Type Operation00IsolatedFactory defaultZone is programm

Page 195

Manual Euro-MERiDIANChapter 13 Page 13 - 9Type Operation13 DayAlarmWhen system SET:Audible response: FullCommunicator:‘Intruder’ signalWhen system UNS

Page 196 - Issue 3·1 – September 2002

Castle Care-Tech Ltd. EngineeringPage 13 - 10 Chapter 13Types 13, 15-17 are NOTavailable on Euro-22/28.Newly programmed zones willNOT be live, and the

Page 197 - Page B - 4 Appendix B

Manual Euro-MERiDIANChapter 13 Page 13 - 11ZONE ATTRIBUTESAny zone may be programmedwith any combination of theseattributes, except as shown.Attribute

Page 198

Castle Care-Tech Ltd. EngineeringPage 13 - 12 Chapter 13PROGRAMMING STEPSWith the display showing CHANGE ZONES?Press YES Zone Number [01]Pre