Castle Care-Tech Ltd. Engineering
Page 16 - 2 Chapter 16
operation MUST be those on
which the zones are live (ie as
shown in the table on page 4-5).
Tags for Ward Control
operation are programmed
through the Manager Menu.
The Ward Controller provides
‘Alarm’ and ‘Can Set’ outputs
dedicated to that Ward. It also
provides relevant indications,
including Set/Unset status, so
should always be located
adjacent to the controlling
Keyswitch where this is used.
If the option ‘Auto Readmits
when set’ is selected as
‘ALWAYS’ then the ward will
always set when the area in
which it located is set. If
selected as ‘NEVER’ it will always
require manual setting.
The Ward must ALWAYS be
unset manually.
An additional option is available
(within the ‘SITE OPTIONS’
menu, to permit a
‘misoperation’ (abort) signal to
be generated by silencing an
alarm at the Ward Controller.
Operation of the Ward
Action Status Notes
Normal (unset)
status
Zones within Ward are
inactive.
‘
Unset
’
indication lit.
Ward zone
triggered
No response
Attempt to set
Ward with zone in
fault
-‘
Fault
’
LED flashes and
intermittent tone to
indicate
‘
cannot set.
’
Set Ward with no
faults
Ward sets (zones live)
‘
Unset
’
indication goes
out.
Ward zone
triggered
Alarm generated
‘
Alarm
’
LED lights,
alarm tone generated.
Ward Controller
unset
Ward Unsets
‘
Unset
’
indication
lights.
Valid code entered
at a Keypad whilst
alarm running
Alarm silenced Ward remains set.