Chapter 14 Page 14 - 3
Euro-MERiDIAN
Time 13:48
Note: The system will give correct
communicator response to the setting,
and any resulting alarms (including
sequential confirmation,
if the
selected zones make a valid
combination
).
On unsetting (with Engineer or
User code), the system will revert
to normal mode.
If the system has been set by any
other code, the Engineer code
will NOT unset the system.
SOAK TESTING ZONES
Any zone (except ‘Final Exit’
types) may be placed on 'soak
test' to prevent it from
generating an alarm.
If the zone triggers whilst the
area(s) in which it is located is
set, it will indicate the
activation (at unset) and enter
details in the system log.
The 'SOAK CONTROL' facility is
accessed through the 'Engineer
Tests' menu. This provides
means of identifying which
zones are on soak, selecting
and removing zones, as well as
specifying the time that they
are to be on test before
automatic removal from test.
NOTE: If additional zones are
placed on test without
removing previously tested
zones, they will be returned to
soak test.
ENGINEER TEST FACILITIES
With display showing
ENGINEER TESTS?
Press YES
Walk Test?
Walk Test
permits the
detectors on the system to be
tested
NOTE: It is necessary to exit
engineering to ‘set’ programming
changes before Walk Test or
Outputs Test can be performed.
Press NO
Walk Test
Areas [ABCD]
Use
A B C
and
D
to select
area(s) to be tested. These
keys will illuminate whilst
selection is made.
Press YES
Walk Test
Front door
Display scrolls through all
programmed zones in areas
selected.
As test is conducted, system
chimes, and zone tested is
removed from scrolling
display, until
Walk Test
Completed
Press NO
Walk Test?