Castle Care-Tech Ltd. Engineering
Page 13 - 30 Chapter 13
Type Default Active Restore
0213 Sec. Intr. A As 013 for Area/Level A events only
0214 Siren A As 014 for Area/Level A events only
0215
French Siren A
As 015 for Area/Level A events only
0216 Strobe A As 016 for Area/Level A events only
0217
Omit rearm A
As 017 for Area/Level A events only
0219 Can Set A As 019 for Area/Level A events only
0220 Exit Starts A As 020 for Area/Level A events only
Then the pattern from 201 to 220 repeats for each other area, so that
0221
-
240 Area/Level B
0241
-
260 Area/Level C
0261
-
280 Area/Level D
0281
-
300 Area 0
0301
-
320 Area 1
0321
-
340 Area 2
0341
-
360 Area 3
0361
-
380 Area 4
0381
-
400 Area 5
0401
-
420 Area 6
0421
-
440 Area 7
0441
-
460 Area 8
0461
-
480 Area 9
1xxx Follow zone xxx When zone xxx is activated When zone clears
ie add 1000 to the zone number to select the output required.
These output types are available throughout the range. See also type 035 (with
additional programming options) when using the Euro
-
134 and 256.
NOTE: The following additional configurations are available, but are
NOT
programmable:
Area Sounder
At output 2 of TMZ (fixed as loudspeaker), a
reas selected in ‘Assign
Keypads’ section - see page 13-15
Watchdog At terminals A (Euro-44+ and above only), selected by jumper J1 – see
13-33