Manual Euro-MERiDIAN
Chapter 13 Page 13 - 5
(iii) MODE SELECTION
This programmes whether the
End Station and any Zone
Expanders enabled will be used
in End of Line (default) or iD
detection mode. This choice
only exists on the Euro-44+ and
above, smaller models are fixed.
The further choice of Single or
Double resistor End of Line
configuration for is global
including Keypads etc.
As part of the MODE SELECTION
menu, the ZONE RESPONSE time
should be programmed. This
selects the time that a zone
trigger must be present before
the system responds by
generating an alarm, and is
programmable from 100mS (0.1
sec) to 3 seconds. This is a global
selection.
NOTE: settings below 400 mS or
above 800mS do NOT comply
with EN.50131 or BS.4737, and
are provided purely for
diagnostic purposes. Higher
settings are more resistant to
false stimuli / interference.
With display showing
CHOOSE MODE?
Press YES
Detection Mode
EoL [ 1]
Use
D
to select between iD
[0] and EOL [1]
Press YES
EOL Mode
DR [ 1]
Use
D
to select between
SR [0] (for single resistor)
and DR [1] (for double
resistor)
Press YES
Zone Response
800 mS [08]
Adjust this setting for
diagnostic purposes only.
Press YES
Zone XDF
Dynamic [0]
DO NOT CHANGE THIS
SETTING, unless specifically
advised to do so by Castle
Care-Tech Ltd. Technical
Support staff.
Press YES
CHOOSE MODE?
Press NO
Moves to next menu item
NOTES:
When a ZEM is enabled, its
detection mode will automatically
be set up as shown in the table on
page 13-7.
Zones wired from Keypads / Tag
Readers will always be ‘End of
Line,’ regardless of mode
selected.