Vue de la page 39
Manual Euro-MERiDIAN
Chapter 7 Page 7 - 1
C
C
h
h
a
a
p
p
t
t
e
e
r
r
7
7
PARTITIONING THE SYSTEM
This chapter identifies the alternative methods of sub-dividing the
system for operating convenience.
Please refer also to the BSIA “Guidelines for Intruder Alarm Systems
Incorporating Split Systems.”
A: SECURITY PATTERNS
a) LEVEL SETTING
(Euro-10, 12, 22 and 28, also
option on Euro-44+)
The user may set security
level A
or B or C or D
. Each level will
provide a different pattern of
coverage, determined by the
programming of the zones.
For example, the front door may
need to be active in all setting
scenarios, so would be programmed
to levels
A, B, C
and
D
. On the other
hand, the master bedroom may
need to be active only if ALL of
the system is set, and would
therefore be allocated to level ‘A’
only. The kitchen may need to be
omitted when the dog is left at
home and at night, and would thus
be programmed to ‘A’ and ‘C’ – etc.
b) AREA SETTING
(Euro-134 and 256, also default
option on Euro-44+)
The user has the option of
setting any combination of
independent areas, and of
adding to
or
subtracting from
the list of areas set at any time.
Euro
-
44+ has four such areas, Euro
-
134 eight and Euro
-
256 fourteen.
Areas may be operated
independently and simultaneously
at different setting points.
Software 3·00: If a code is entered
whilst some areas are set, the
default response will be to SET
remaining areas for which the
code is valid, UNLESS entry time has
started, when the response will be
to UNSET relevant areas. This
response will be modified by the
use of ‘flexi-set’ codes.
Software 1: If a code is entered
whilst some areas are Set, the
default response will be to UNSET
those areas for which the code is
valid, leaving remaining areas Set.
This is not affected by the ‘flexi-set’
attribute.
If multiple areas are set
simultaneously, the system will use
the highest mode / time / volume
for which the setting keypad is ‘IN.’
Other areas will ‘quickset.’
When entry time is started, the
longest time / highest volume
Vue de la page 39