Manual Euro-MERiDIAN
Chapter 13 Page 13 - 35
Option Function
Set with
Technical
Fault
Permits the system to
be set if a Mains, Battery,
Telecom Line, or other
System fault is present.
Set Ward
with
Technical
Fault
Permits a Ward to be set
if a relevant Mains,
Battery, Telecom Line, or
other System fault is
present
Set Fail =
Alarm
If NO, exit time will
continue until exit route
is clear.
If YES, a graduated alarm
will be generated when
Set Fail
timer expires, if
exit procedure is still
incomplete.
Do
Battery
Load Test
Programmes the system
to perform a full load
test of the battery at
7.00 am each day
Ward Mis
-
operation
Permits Misoperation
(abort) signal to be
generated without the
entry of a valid code
into the system when
Blockschloss or Ward
operated after an alarm.
Strobe
Confirm
If selected, a
STROBE
ANY
output will be live
for 5 seconds as the
system sets.
Use with care, in view of
potential security risk.
Option Function
Rearm
Isolates
At rearm (reinstatement)
at end of confirmation
time, forces zone
(NOT
system tamper) causing
unconfirmed alarm to
be isolated, whether still
in fault or not.
Leave
Open
Menu
Permits simple omission
of omittable zones in
fault at time of setting.
Code
Stops
Sound
Entry of a code which is
valid for the system (but
not for the area in which
an alarm has been
generated) will silence
alarm, and generate a
Misoperation signal
leaving area set, and
other output conditions
valid.
Use with care, in view of potential
security risk.
E/E
Keypads
only
Entry and Exit tones will
sound on keypads only,
NOT on system
loudspeaker.
Use Level
set
Permits Euro
-
44+ to
function in
Level
setting
mode. See page
13-10
Confirmed
When Final
Set
(or When
exit starts)
Selects between
Confirmation signal
being available only
when system finally set
(mandatory for
DD243:2002), or from
start of exit time.
NOTE: This option MUST be set for ‘exit
starts’ to be entered in logs.