C: AREA SIGNALLING
‘Set/Unset’ ‘Intruder’ ‘Hold Up’
‘PA’ and ‘Confirmation’ signals
are available for each area
individually.
D: FUNCTIONALITY
The following functionality
should be noted:
PA etc SIGNALLING
‘Zone
PA’
triggers ONLY for an
alarm generated from
a PA ZONE
‘Duress’
triggers ONLY for an
alarm generated at a
keypad
‘Hold
Up’
triggers for alarms
generated by a zone
OR at a keypad
Please ensure that communicator
signals are selected carefully -
see page 8-1.
Alarm Responses
The alarm response may be
programmed individually for
each area (and for ‘Fire’ and
‘Day’ alarms). This may be done
on a ‘graduated’ basis – eg
system warnings may start at
keypad bleepers only, and
progress through internal
sounders to external sounders
(15 seconds at each level). This
response may be programmed
to ‘upgrade’ to start at digi
response if additional areas are
set, and again to confirmed
response if all areas are set.
Entry Pre-Alarm Timer
Introduces a programmable
delay before triggering of the
‘intruder’ signal, if the alarm is
generated after entry time has
started.
NOTE: For correct operation to
comply with the requirements of
DD243:2002, this should be set
to 30 seconds or equal to entry
time if shorter.
Siren Delay
This may be programmed to
suit appropriate requirements.
The delay will apply to any
alarm generating an ‘intruder’
communicator signal, but will
NOT be valid:
A: Within 3 minutes of
setting the system
B: After entry time has
started.
A separate 'Silent First Alarm'
option is available when
confirmation signalling is used.
Rearm
When the "Siren" Time expires,
the system will silence. Re-arm
(re-instatement) will NOT take
place until expiration of the
"confirmation" timer. Re-arm
may be programmed between
0 (never) and 9 (always).
At rearm, any zone in fault will
be omitted, and a 'zone
isolated at rearm' signal
generated. The zone will be
reintroduced should it
subsequently close, unless ‘Re-