Castle Care-Tech Ltd. Engineering
Page 20 4 Chapter 20
End Station, ALL POWER MUST
BE DISCONNECTED.
The card must be slotted into
the correct socket (labelled P20)
on the End Station. This is the
UPPER socket on Euro-22/28,
and RIGHT hand socket on Euro-
44+. It is the only socket on
Euro-10/12.
The notched end must be to
the LEFT (Euro-10/12/22/28) or
TOP (Euro-44+), as follows:
Should it be necessary to
remove the unit, the reverse
procedure should be
performed, ensuring that all
power is removed before doing
so.
E: PSTN Wiring
Connections are made to
terminals on the End Station
PCB,
T A Line A in
T B Line B in
T C Line A out
T D Line B out
T E Telecom Ground
Before making these
connections, ALL POWER
MUST BE DISCONNECTED
from the system.
The Telecom Ground
terminal (TE) should
ALWAYS be connected to
earth in order to maximise
the effectiveness of the
transient voltage
protection on the unit.
The cable must be fed into the
End Station housing through
the hole provided, protected
Note that the approvals
standard TBR21 clause 4.2
requires connection to be
made via an RJ11 plug
and socket.
Failure to do so will
leave the device
vulnerable to damage
during electrical
storms, etc.