EMERGENCY ALARMS
This chapter discusses the facilities included in Euro-MERiDIAN for
emergency situations.
NOTE: Emergency zone types are NOT active whilst the system is in
engineer mode.
A: PERSONAL ATTACK/
DURESS ALARMS
Facilities for Personal Attack
alarms are:
1 Deliberately
operated
device wired
into zone
programmed
as
‘
PA
’
:
Full audible
alarm, and
communicator
‘
Hold Up
’
and
‘Zone
PA
’
signals
to Alarm
Receiving Centre
2 Deliberately
operated
device wired
into zone
programmed
as
‘
Silent PA
’
:
Silent
communicator
‘
Hold Up
’
and
‘Zone
PA
’
signals
to Alarm
Receiving Centre
3Use of a
‘
Duress
’
code
(
programmable
only by
engineer).
Silent
communicator
‘
Hold Up
’
and
‘
Duress
’
signals
to Alarm
Receiving Centre
whilst unsetting
system.
42
-
Key PA
from Keypad
(keys
1
and
7
)
Default is audible
alarm only.
Options are
available for
communicator
‘
Hold Up
’
and
‘
Duress
’
signals,
and for
‘
silent
’
operation.
NOTE: This
function must be
enabled in ‘Site
Options.’
NOTE: please ensure that
communicator signals are selected
carefully:
‘
ZONE
PA
’
triggers ONLY for an
alarm generated from
a PA ZONE
‘
Duress
’
triggers ONLY for an
alarm generated at a
keypad
‘
Hold
Up
’
triggers for alarms
generated by a zone
OR
at a keypad