ENGINEER SYSTEM SET
This permits the engineer to
set / unset the system using his
code.
With display showing
Euro-MERiDIAN
Time 13:45
Enter Engineer code
(default
1111
SET SYSTEM?
Press YES
Set Areas
[ABCD]
Select areas/level required
to be set, noting that the
Area keys will illuminate to
reflect the choices made.
Press YES
Setting [30]
Full
The system will commence
setting, in
Timed
mode.
Exit time will count down,
and system set.
Euro-MERiDIAN
Time 13:48
Note: The system will give correct
digicom response to the setting,
and any resulting alarm.
On unsetting (with Engineer or
User code), the system will revert
to normal mode.
If the system has been set by
any other code, the Engineer
code will NOT unset the system.
ENGINEER FORCE SET
This permits the engineer to
set / unset the system using his
code, forcing it to set despite
zones in fault condition, and
nominate which zones must be
triggered to generate an alarm
condition
With display showing
Euro-MERiDIAN
Time 13:45
Enter Engineer code, default
1111
SET SYSTEM?
Press NO
FORCE ARM ON 1st
ZONE? [01]
Nominate number of zone to
generate alarm once set, eg
Press
05
and YES
FORCE ARM ON 2nd
ZONE? [01]
Nominate number of
additional zone to generate
alarm once set, eg
Press
13
and YES
Set Areas
[AB ]
Select areas / level required
to be set, noting that the
Area keys will illuminate to
reflect the choices made.
Press YES
Quick Setting . .
The system will set with
minimum 5 second exit time.