Manual Euro-MERiDIAN
Chapter 16 Page 16 - 3
Programming a Ward:
With the display showing
ASSIGN KEYPADS/
READERS?
Press YES
Address
[0]
Select address required, eg
Press
4
Address
[4]
Press YES
Type
Not Used [2]
Use
D
to select
Reader [1]
Press YES
Reader is [0]
Set Point
Use
D
to select
Ward Control [1]
Reader is [1]
Ward Control
Press YES
Ward Zones _ _
None
Use number keys, followed by
YES
to select the zones that
are to be within the ward
controlled. These will scroll
continuously to identify those
selected
-
eg to select zone 4,
key
04
(or
004
) and
Press YES
Ward Zones 04
Parts Store
Zones to be entered onto a
Ward List MUST already be
enabled in programming as
intruder zones.
To delete a zone already
present in the list, simply enter
the zone number again.
When the Ward List is complete, to
escape from the menu
Press
NO
Auto Readmits
When Area Set [0]
Use
D
to select between
When Area Set [0]
or
Never
[1]
Selecting
When Area Set
forces the Ward to set
whenever the area in which it i
s
located is set. Selecting
Never
leaves the Ward to be set
independently of the area in
which it is located. Unset is
always independent.
Press YES
Ward Control By
Tag [0]
Use
D
to select between
Tag
[0]
or
Zone [1]
Select
Tag
to programme the
Ward to be controlled by
presentation of a valid tag at
the Reader.
Select
Zone
selection to
permit the Ward to be
controlled by a Keyswitch. This
Keyswitch must be wired into
Input 1 of the controlling Tag
Reader.
Press YES