Manual Euro-MERiDIAN
Chapter 4 Page 4 - 3
E: ELECTRICAL SPECIFICATIONS
Mains
Supply
230v (220 to 240v) AC.
Max 250mA
Fuse 1.2A PS:
1
½
A PS
2
½
A PS
150m
A
250m
A
500m
A
slow blow
Euro
-
10/12 END STATION
:
Power
Supply
13.75v DC
1.2 A (800mA continuous) or
1
½ A (1A continuous)
Battery 2.9 or 7Ah
Fuses:
Battery 1.5A quick blow
12v outlets 800mA quick blow
Euro
-
22/28 END STATION
:
Power
Supply
13.75v DC
1
½
Amp (1A Continuous)
Battery 7Ah
Fuses:
Battery 1.5A quick blow
12v outlets 800mA quick blow
Euro
-
44+ END STATION:
Power
Supply
13.75v DC
1
½
Amp (1A continuous) or
2
½
Amp (1
½
A Continuous)
Battery 7Ah or 17Ah
Fuses:
Battery 3.15A quick blow
12v outlets 800mA quick blow
All
system power supplies are
monitored continuously
Condition and charging of
all
batteries
are continuously monitored, with
battery
‘
load
’
testing available.
Batteries protected against deep
discharge (Euro-44+ and above).
INTELLIGENT POWER SUPPLIES:
‘‘3" housing
(standard)
‘‘4" housing
Power
Supply
13.75v DC
1
½
A *
(1A continuous)
13.75v DC
2
½
A
(1½ A continuous)
* Suitable for maximum
instantaneous loads (up to 15
seconds) of 2
½
A.
Battery 7 Ah 7Ah or 17Ah
Fuse:
Battery 3.15A quick blow
Quiescent Current Drain:
Euro-10/12 End Station 70mA
Euro
-
22/28 End Station 75 mA
Euro
-
44+ End Station 90 mA
Standard Keypad B/L ON 130mA*
Standard Keypad B/L OFF 60mA*
Deluxe Keypad – B/L on 150mA*
Deluxe Keypad – B/L off 80mA *
Set/Unset Tag Reader 60mA *
* Plus 10mA in alarm condition.
TMZ zone expander 40mA
ZEM Zone Expander 40mA
Output Module 40mA
Access Door Station 100mA
External Reader Head 60mA
MSX Card
Slot
-
in Digi
-
modem