Band dispenser is too stiff
The screws may have become too tight. The lock washers should be slightly
compressed, but not fully flattened. Locate and adjust as appropriate.
The Finger Slides may have become dry. Try lubing them with silicone grease or dry
white graphite. Do not use liquid oil as it may drip onto the tape.
Glue pot failing to fill even though fill cycle is activating
repeatedly
The Glue Magazine may have become packed and should be dumped and refilled, or
tapped with the heel of your hand to settle the glue into whatever air spaces may have
developed. To prevent this, make sure that the Glue Magazine isn’t filled over
halfway to the top.
Check the air pressure and confirm that there is a minimum of 80 PSI coming from the
compressor.
Check that the Glue Hopper has not become packed. Castle recommends that the
Hopper be changed periodically because they will gum up after prolonged exposure to
glue fumes.
In the Magazine, check the position of the Shooter Tube above the Shooter Nozzle.
The proper gap is one half an inch.
Check the Shooter Tube for kinks.
Glue pot failing to fill and no fill cycle activated
Check the air supply.
Confirm that the glue is melted.
Check the small black and white Control Tubes for kinks and blockages.