Castle Equalizer Edgebander Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
12
Rest Mode
Definition:
The Equalizer will enter Rest Mode if it remains
un-cycled for more than 18 minutes
when it is in Run Mode. While the Equalizer is in Rest Mode, the glue will be
maintained at a slightly lower temperature then when in Run Mode and the light will
blink a ½ second on and a ½ second off.
HOW TO start Rest Mode:
Rest Mode will be automatically engaged only after the Equalizer remains un-cycled
for more than 18 minutes when in Run Mode.
Guidelines:
Do not attempt to apply glue while the Equalizer is in Rest Mode.
Do not attempt temperature adjustment while in Rest Mode.
To “wake up” the Equalizer, simply depress the Guillotine Actuator and wait for the
Strobe to stop blinking.
The glue should take less than 10 minutes to warm up from Rest Mode.
Sleep Mode
Definition:
The Equalizer will enter Sleep Mode if it remains
un-cycled for more than 18
minutes when it is in Rest Mode. While the Equalizer is in Sleep Mode it is
essentially powered down completely. The light will be off and the glue heater will
be off, but it will enter the Warm-Up Mode if the Guillotine Actuator is depressed
just once.
HOW TO start Sleep Mode:
Sleep Mode will be automatically engaged only after the Equalizer remains un-
cycled for more than 18 minutes when in Rest Mode.
Guidelines:
Do not attempt to apply glue while the Equalizer is in Sleep Mode.
Do not attempt temperature adjustment while the Equalizer is in Sleep Mode
To “wake up” the Equalizer, simply depress the Guillotine Actuator and wait for the
Strobe to stop blinking.
The glue can take about 18 minutes to warm up from Sleep Mode.
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 27 28

Commentaires sur ces manuels

Pas de commentaire